Harbor Freight Tools 67026 Cordless Saw User Manual


 
SKU 67026 For technical questions, please call 1-800-444-3353. Page 13
MAINTENANCE AND
SERVICING
Procedures not specically
explained in this manual
must be performed only by a
qualied technician.
TO PREVENT
SERIOUS INJURY
FROM ACCIDENTAL
OPERATION:
Turn the Power Switch of the
tool off and remove Battery
Pack before performing any
inspection, maintenance, or
cleaning procedures.
TO PREVENT SERIOUS
INJURY FROM TOOL
FAILURE:
Do not use damaged
equipment. If abnormal noise
or vibration occurs, have the
problem corrected before
further use.
Cleaning and Maintenance
BEFORE EACH USE,1. inspect the
general condition of the tool. Check
for loose screws, misalignment or
binding of moving parts, cracked or
broken parts, damaged electrical wir-
ing, and any other condition that may
affect its safe operation.
AFTER USE,2. wipe external surfaces
of the tool with clean cloth.
Troubleshooting
Problem Possible Causes Likely Solutions
Tool will not start. Battery Pack not properly 1.
connected or charged.
Tool’s thermal reset breaker 2.
tripped (if equipped).
Internal damage or wear. 3.
(Carbon brushes or switch, for
example.)
Connect fully-charged Battery Pack 1.
completely.
Turn off tool and allow to cool. Press 2.
reset button on tool.
Have technician service tool.3.
Performance
decreases over time.
Blade dull or damaged.1.
Carbon brushes worn or 2.
damaged.
Keep blade sharp. Replace as needed.1.
2.
brushes.
Excessive noise or
rattling.
Internal damage or wear. (Carbon
brushes or bearings, for example.)
Have technician service tool.
Overheating. Forcing tool to work too fast.1.
Blade misaligned. 2.
Blade dull or damaged.3.
Blocked motor housing vents.4.
Allow tool to work at its own rate.1.
Technician must check and correct blade 2.
to fence alignment.
Keep blade sharp. Replace as needed.3.
Wear ANSI-approved safety goggles and 4.
NIOSH-approved dust mask/respirator
while blowing dust out of motor using
compressed air.
Follow all safety precautions whenever diagnosing or servicing the
tool. Disconnect power supply before service.