Harbor Freight Tools 97526 Nail Gun User Manual


 
Page 7
SKU 97526
For technical questions, please call 1-800-444-3353.
INSPECTION, MAINTENANCE, AND CLEANING
1. WARNING! Make sure air compressor is unplugged and that the Nailer is
disconnected from its Air Supply before performing any inspection, maintenance,
or cleaning procedures.
2. BEFORE EACH USE, inspect the general condition of this tool. Check for
loose screws, misalignment or binding of moving parts, cracked or broken parts,
damaged air hoses, and any other condition that may affect its safe operation. If
abnormal noise or vibration occurs, have the problem corrected before further use.
Do not use damaged equipment.
MAINTENANCE CHART
Maintenance Type
Before
Use
After
Use
Monthly
Inspect the Nailer for damage
(see #2, above)
X X
Wipe off with clean, moist
cloth
X X
TROUBLESHOOTING
Problem Possible Causes Probable Solutions
Air leak near top of
tool or in trigger area.
1. Loose screws.
2. Worn or damaged o-rings or seals.
1. Tighten screws.
2. See qualied service technician for
repairs.
Nailer does not
operate or operates
sluggishly
1. Inadequate air supply.
2. Inadequate lubrication.
3. Worn or damaged o-rings or seals.
1. Check screws.
2. See qualied service technician for
repairs.
Air leak near bottom
of Nailer
1. Loose screws.
2. Worn or damaged o-rings or
bumper.
1. Tighten screws.
2. See qualied service technician for
repairs.
Nailer jam frequently 1. Incorrect fasteners.
2. Damaged fasteners.
3. Magazine or Nozzle screw loose.
4. Magazine is dirty.
5. Driver is worn or damaged.
1. Check fasteners for correct size.
2. Replace with undamaged
fasteners.
3. Tighten screws.
4. Clean screws.
5. See qualied service technician for
repairs.
Other See qualied service technician for
repairs.