Heath Zenith 52-4477-8 Work Light User Manual


 
7
598-1285-00
TROUBLESHOOTING
If you experience a problem, follow this guide.
No Service Parts Available for this Product
SYMPTOM POSSIBLE CAUSE SOLUTION
Lights will not
come on.
1. Light switch is turned off.
2. Lamp is loose or burned out.
3. Fuse is blown or circuit breaker is turned off.
4. Daylight turn-off is in effect.
5. Incorrect circuit wiring, if this is a new installation.
6. Sensor not detecting movement.
1. Turn light switch on.
2. Check lamp and replace if burned out.
3. Replace fuse or turn circuit breaker on.
4. Recheck after dark.
5. Verify wiring is correct.
6. Re-aim the sensor to cover desired area.
Lights come on in
daylight.
1. Light control may be installed in a relatively dark
location.
2. Light control is in TEST.
1. e fixture is operating normally under these condi-
tions.
2. Set control switch to 1, 5, or 10 minutes.
Lights come on
for no apparent
reason.
1. Light control may be sensing small animals or auto
-
mobile traffic.
2. Sensitivity is set too high.
1. Re-aim sensor.
2. Reduce sensitivity.
Lights stay on
continuously.
e sensor may be picking up a heat source like an air vent,
dryer vent, or brightly painted, heat-reflective surface.
Re-aim sensor.
Reduce sensitivity.
Lights flash on
and off.
1. Light control is in the TEST mode and warming
up.
2. Heat being reflected from other objects may be af
-
fecting the sensor.
1. Flashing is normal under these conditions.
2. Re-aim sensor