HP (Hewlett-Packard) AXCRN3-2G Welder User Manual


 
13 Integrated Lights Out Console Management Devices
This chapter contains information that applies to the integrated lights out (iLO and iLO2) console
management device.
13.1 iLO2 Devices In Server Blades Can Hang
There is a known problem with the iLO2 console management devices that causes the iLO2
devices to hang. This particular problem has very specific characteristics:
This problem is typically seen within one or two days of the initial cluster installation.
Most of the time, but not always, all iLO2 devices in a particular enclosure hang at the same
time.
The problem usually affects multiple enclosures.
The work around for this problem is to completely power cycle the entire cluster (or at least all
enclosures) after the initial cluster installation is complete or if the problem is encountered. This
problem has never been reported after the power has been cycled and the cluster is in its normal
running state.
This problem is targeted for resolution in iLO2 firmware Version 1.28, but at the time of
publication, had not been tested yet.
13.1 iLO2 Devices In Server Blades Can Hang 43