OM-478 Page 19
ether1 7/96 ST-153 382-A / ST-180 933
Y Stop engine.
Y Improper handling or expo-
sure to ether can harm your
health. Follow manufactur-
ers safety instructions on
cylinder.
Y Do not use Ether Starting Aid
while engine is running.
Open side door(s).
1 Ether Cylinder
2 Nozzle
Remove cover and clean cylinder
nozzle.
3 Clamp
4 Fitting
5 Cap
6 Valve
Remove cap and clean fitting.
Install cylinder on fitting. Tighten
clamp.
. After installing cylinder, wait at
least 10 minutes before using
to let ether particles settle and
prevent atomizer plugging.
Put cap on fitting when cylinder is
removed.
1
2
3
4
6
5
4-7. Installing Ether Cylinder (Optional Ether Starting Aid)
4-8. Remote 14 Receptacle RC3 Information
Socket* Socket Information
A 24 volts ac. Protected by circuit
breaker CB4.
AJ
B
K
I
C
L
NH
B Contact closure to A completes 24
volts ac contactor control circuit.
D
M
G
E
F
I 115 volts ac. Protected by circuit
breaker CB3.
J Contact closure to I completes 115
volts ac contactor control circuit.
OR
G Circuit common for 24 and 115
volts ac circuits.
OR
C 0 to +10 volts dc output to remote
control from min to max of Amper-
age/Voltage control R1.
A/V
D Remote control circuit common.
A/V
E 0 to +10 volts dc input command
signal from remote control.
Ref. ST-800 729-A
K Chassis common.
*The remaining sockets are not used.