3-7. Water-Cooled Gun Connections
1 Gas Hose
Connect to Gas fitting on feeder.
2 Water Hose
Connect to Water To Gun fitting on
feeder (left-hand threads).
3 Wire Conduit
4 Thumbscrew
5 Wire Conduit Block
Loosen thumbscrew, and insert
conduit through Wire opening until
it bottoms against block. Tighten
thumbscrew.
6 Gun Control Cable
Insert plug into Gun Control recep-
tacle, and tighten threaded collar.
7 Strain Relief
Remove strain relief as shown.
8 Power/Water Cable
Route cable through strain relief
and connect to Weld/Water From
Gun outlet on feeder. Reinstall
strain relief. Close and latch door.
Ref. 151 778-B / 152 456-A
1
2
3
6
8
7
43
5
5/8, 1-1/8 in
Tools Needed:
Left Side