Honeywell 4820i Work Light User Manual


 
3 - 3
Base Charge Mode
In order for the battery to be charged, there must be enough voltage for the cir-
cuitry to work. There are three methods during which power can be supplied to
the base:
1:9VDC power supply connected to the barrel connector
2:12VDC host power source only
3:5VDC host power source only
The chart below describes each selection by condition.
Using a slow charge rate draws less current (power) from the input power
source when the battery is mostly discharged.
Note: If you attach the 4820 system to a host with a 12V power source, the 12V
host is dominant; the system pulls power from the host and not the 9V
power supply. For example, if you have a host system with a 12 volt
available to the base, it will supersede the 9V power supply. The 9V
supply is not needed for 12V host applications and only serves as a
backup if the system goes down.
Scan the appropriate bar code for your application.
Default = Automatic
.
123
Automatic Fast Charge Slow Charge No Charge
Full Charge Rate Fast Charge Fast Charge No Charge
Low Charge Rate Slow Charge Slow Charge No Charge
Battery Charge Off No Charge No Charge No Charge
* Automatic
Low Charge Rate
Full Charge Rate
Battery Charge Off