13. Setting the Angle of the Column
Remove the column lock bolt (1)
Loosen bolt on back support bracket (2).
The column can now be pulled into the desired
position, 0 to 45 degrees. Side decal provides
approximate measurements. If greater precision is
required use alternate measuring techniques.
Maximum column range is 45 degrees. Indictor strip
on the column shows various degrees (3).
14. Mounting the Drill Carriage
Risk of injury!
Always disconnect the power before mounting the drill carriage to the drill motor. Fingers
may be crushed between the column and drill carriage. For this reason, when mounting the
drill carriage, keep one hand on the handle and the other hand on the drill motor.
Align the column.
Mount the drill carriage.
15. Operating the Feed
Drilling into a live external power supply line can cause a fatal injury as the drill may
conduct current and voltage. A Ground Fault Circuit Interrupter (GFCI) offers no protection
in such situations, therefore care must be taken prior to drilling to ensure that electrocution is
avoided.
The use of levers or extensions to increase drilling pressure is prohibited. In order to
prevent the drill bit being damaged, it is important to ensure that the diamond core bit is
supplied with sufficient cooling water. Operate the feed handle manually.
The feed handle is designed to facilitate handling of the drill
and its flexible left/right hand fitting enables convenient
adaptation to individual drilling situations. The feed handle
can be switched to the other side as follows:
Pull off the feed handle in an axial direction.
Slip the feed handle onto the axle shaft on the opposite side.
A loose feed handle on the shaft may cause you to lose
control of the drill. For this reason, always ensure that the
feed handle is securely fitted on the shaft.
1
2
3
124