8.0 GENERAL INFORMATION
8.2 INSTALLATION DRAWING − N55/75K−CC & N75/100H−CC − AIR COOLED
KEY
A 2” NPT Air discharge (Female) 60Hz units
2” BSP Air discharge (Female) 50Hz units
B Ø63mm (2.48”) Electrical inlet
C 0.38“ NPT (Female)
Note: Pipe condensate drain lines separately to an open
drain due to differences in drain pressures. Use drain
lines at least as large as the connection. Read operations
manual and check local regulations
D Cooling airflow
E Exhaust airflow
F Cabinet cooling airflow
G 4 x Ø 13.0mm (0,5”)
Compressor should be bolted to the floor with
four M10 (0.38”) bolts using holes shown. Seal
base to floor with cork or rubber.
H INTELLISYS Controller
U Right
V Bottom
W Front
X−X Section through X−X
Y Rear view
Z Plan view