Kawasaki 691204 Saw User Manual


 
This Cut-off saw is equipped with a grounded 3-wire power cord with a 3-prong
plug. If the power cord will not fit into the wall plug, an approved adapter can be
used as long as it is connected to the center screw in the wall plate. See Figure 1
and the steps below to use an AC grounding adapter:
1. Remove the cover plate mounting screw.
2. Insert the AC grounding adapter into the bottom receptacle so the green
grounding lug fits over the screw hole.
3. Install the mounting screw back into the cover plate securely affixing the
adapter to the receptacle.
NNeevveerr mmooddiiffyy tthhee eelleeccttrriiccaall aaddaapptteerr bbyy ccuuttttiinngg ooffff tthhee
ggrroouunnddiinngg pprroonngg ssoo iitt wwiillll ffiitt iinnttoo uunna
apppprroovveedd,, uunn--ggrroouunnddeedd eelleeccttrriiccaall rreecceepp--
ttaacclleess.. FFaaiilluurree ttoo ffoollllooww tthhiiss pprroocceedduurree ccoouulldd rreessuulltt iinn bbuurrn
nss,, sseevveerree eelleeccttrrii--
ccaall sshhoocckk,, oorr eevveenn ddeeaatthh..
If you have questions about connecting the Cut-off saw, contact a certified
electrician to install the proper circuitry needed for this and other power tools
you use. Repair or replace any damaged electrical wiring
IIMMMMEEDDIIAATTEELLYY..
EEXXTTEENNSSIIOONN CCOORRDD UUSSAAGGEE
Extension cords are not recommended for use with this saw. Extension cords, if
used, must be properly grounded with a 3-prong plug on one and a 3-hole recepta-
cle on the other.
DDOO NNOOTT uussee ggrroouunnddiinngg aaddaapptteerrss wwiitthh aann eexxtteennssiioonn ccoorrdd..
Extension cords must be UL listed and use a minimum of 18 A.W.G. wiring.
Extension cords should never exceed 25 feet in length. Extension cords, that are too
long, cause a voltage drop over the extra distance causing the saw motor to run
slower with the possibility of causing damage to the motor. Using extension cords
with smaller than the recommended wire gauge run the risk of getting too hot, melt-
ing, and/or causing fires. See table, “Extension Cord Specifications”, on page 26.
UUSSEE RREECCOOMMMMEENNDDEEDD AACCCCEESSSSOORRIIEESS..
Consult the owners manual for recommend-
ed accessories. The use of improper accessories may cause cause risk of injury.
NNEEVVEERR SSTTAANNDD OONN TTOOOOLL..
Serious injury could occur if the tool is tipped or if
the cutting tool is unintentionally contacted.
CCHHEECCKK DDAAMMAAGGEEDD PPAARRTTSS..
Before further use of the tool, a guard or other part
that is damaged should be carefully checked to determine that it will operate
properly and perform its intended function. Check for alignment of moving
parts, binding of moving parts, breakage of parts, mounting and any other con-
ditions that may affect its operation. A guard or other part that is damaged
should be properly repaired or replaced.
DDIIRREECCTTIIOONN OOFF FFEEEEDD..
Only feed work into a blade or cutter against the direc-
tion of rotation of the blade or cutter.
GGRROOUUNNDDIINNGG IINNSSTTRRUUCCTTIIOONNSS
NNEEVVEERR uussee aapppplliiaanncceess oorr eeqquuiippmmeenntt tthhaatt hhaavvee mmoottoorrss
wwiitthh aauuttoommaattiicc rreesseett oovveerrllooaadd pprrootteeccttiivvee ddeevviicceess..
TThheessee pprrootteeccttiivvee ddeevviicceess
ccaann ccaauussee uunneexxppeecctteedd ssttaarrttuuppss tthhaatt ccaann ccaauussee pprrooppeerrttyy ddaammaaggee,, sseevveerree ppeerr--
ss
oonnaall iinnjjuurryy,, oorr ddeeaatthh..
The electrical power source for this Cut-off saw
MMUUSSTT
be grounded in order to
prevent possible electric shock or even death should the tool malfunction or break
down. Grounding provides a path of least resistance for electric current thus reduc-
ing the risk of electrical shock. The power source must also use a minimum 20A
service. Multiple power tools should never be used on the same circuit at the same
time.
FFaaiilluurree ttoo pprrooppeerrllyy ggrroouunndd tthhiiss CCuutt--ooffff ssaaww ccoouulldd rreessuulltt iinn
bbuurrnnss,, sseevve
erree eelleeccttrriiccaall sshhoocckk,, aanndd eevveenn ddeeaatthh.. TThhiiss iiss eessppeecciiaallllyy ttrruuee iiff uusseedd iinn
ddaammpp oorr wweett llooccaattiioonnss oorr nneea
arr mmeettaalllliicc pplluummbbiinngg.. TThhee rreeaaccttiioonn ffrroomm eelleeccttrriiccaall
sshhoocckk ccoouulldd ppoossssiibbllyy ccaauussee yyoouurr hhaannddss ttoo mmaakkee ccoonnt
taacctt wwiitthh tthhee ccuuttttiinngg ttoooollss..
NNoott aallll oouuttlleettss aarree pprrooppeerrllyy ggrroouunnddeedd,, rreeggaarrddlleessss ooff tthhee
ttyyppee ooff rreecceepptta
accllee tthheeyy hhaavvee.. IIff yyoouu aarree nnoott ssuurree iiff tthhee rreecceeppttaaccllee iiss pprrooppeerrllyy
ggrroouunnddeedd oorr nnoott,, ccoonnssuulltt aa cceerrttiiffiie
edd eelleeccttrriicciiaann.. TThhee AACC rreecceeppttaaccllee mmuusstt bbee
pprrootteecctteedd bbyy aa dduuaall eelleemmeenntt ttiimmee ddeellaayy oorr aa cciirrccuuiitt bbrreeaakkeer
r..
5
UNGROUNDED AC RECEPTACLE
GROUNDED RECEPTACLE
GROUNDING ADAPTER
CUT-OFF SAW POWER CORD
CUT-OFF SAW POWER CORD
COVERPLATE
MOUNTING SCREW
FIGURE 1. CONNECTING THE CUT-OFF SAW TO THE AC POWER RECEPTACLE