Lincoln Electric 11079 Welder User Manual


 
RANGE SWITCH
The Range switch is used to select one of three
amperage ranges with generous overlap for Stick/TIG
welding, or one Wire Feed welding range.
Never change the RANGE Switch setting while
welding. This will damage the switch.
------------------------------------------------------------------------
CONTROL DIAL
Provides a fine welding current adjustment within the
Range Switch settings in the STICK mode and weld-
ing voltage control with the Range switch set in the
wire feed mode.
Process Range Setting Current Range
POLARITY SWITCH
Provides three selectable welding polarities:
AC, DC+ & DC-
Never change the Polarity switch setting while
welding. This will damage the switch.
------------------------------------------------------------------------
B-2
OPERATION
B-2
RANGER 3 PHASE
CAUTION
CAUTION
KOHLER
20 H.P. COMMAND
.35 Gallons/Hour
(1.34 Liters/Hour)
.76 Gallons/Hour
(2.86 Liters/Hour)
1.23 Gallons/Hour
(4.64 Liters/Hour)
1.38 Gallons/Hour
(5.21 Liters/Hour)
1.22 Gallons/Hour
(4.60 Liters/Hour)
1.52 Gallons/Hour)
(5.77 Liters/Hour)
1.64Gallons/Hour)
(6.23 Liters/Hour)
Low Idle - No Load
2200 RPM
High Idle - No Load
3700 RPM
AC CC Weld Output
225 Amps @ 25 Volts
DC CC Weld Output
210 Amps @ 25 Volts
DC CV Weld Output
200 Amps @ 20 Volts
Auxiliary Power Single Phase
9,500 Watts
Auxiliary Power 3 Phase
10,500 Watts
RANGER 3 PHASE APPROXIMATE FUEL CONSUMPTION
STICK/TIG
(constant current)
(3 range settings)
WIRE FEED
(constant voltage)
(one range setting)
90 Max.
145 Max.
210DC/225AC Max.
15 to 25V
50 to 90 Amps
70 to 145 Amps
120 to 210 (DC) 225(AC)
Up to 200 Amps