Lincoln Electric 225 Welder User Manual


 
A-3
INSTALLATION
PRECISION TIG 225
A-3
SAFETY PRECAUTIONS
SELECT SUITABLE LOCATION
MOUNTING
Environmental Rating
The Precision TIG 225 power source carries an IP21S
environmental rating. It may be used in normal indus-
trial and commercial environments. Avoid using it in
environments which have falling water such as rain.
Read and follow "Electric Shock Warnings" in the
Safety section if welding must be performed under
electrically hazardous conditions such as welding in
wet areas or on or in the workpiece.
• The Precision TIG 225 must be located where there
is free circulation of clean air such that air move-
ment in and out the back air vents will not be
restricted.
• Dirt and dust that can be drawn into the Precision
TIG 225 should be kept to a minimum. Failure to
observe these precautions can result in excessive
operating temperatures and nuisance shutdown.
GRINDING
Do not direct grinding particles towards the welder. An
abundance of conductive material can cause mainte-
nance problems.
STACKING
Precision TIG 225 cannot
be stacked.
LIFTING AND MOVING
The PRECISION TIG 225 models are provided with
an Eyebolt used for lifting the unit with a hoist.
To install; remove the plug button from the case top
and screw the Eyebolt securely into the threaded
bracket beneath the case top per the below instruc-
tions and warnings provided on the case top decal.
Save the removed plug button (LE part No.T10397-2)
to cover the hole when the lift Eyebolt is removed.
An undercarriage, provided on the Ready-Pak™
w/Cart model, is also available to easily move the the
unit. Refer to the Accessories section of this manual.
Do not attempt to lift the power source with an
undercarriage attached.
The undercarriage is designed for hand moving only;
mechanized movement can lead to personal injury
and/or damage to the Precision TIG 225.
TILTING
Each machine must be placed on a secure, level sur-
face, either directly or on a recommended undercar-
riage. The machine may topple over if this procedure
is not followed.
ELECTRIC SHOCK can kill.
Only qualified personnel should
perform this installation.
Turn the input power OFF at the
disconnect switch or fuse box
before working on this equipment.
Do not touch electrically hot
parts.
Always connect the PRECISION TIG 225 to a
power supply grounded per the National Electrical
Code and any local codes.
---------------------------------------------------------------------------
WARNING
Read entire installation section before starting
installation.
• Use only Lincoln provided
T4550-5 1/2-13 x 1.00 eyebolt.
• Fully engage threads and
torque eyebolt to 38 ft. lbs.
• Re-torque eyebolt to 38 ft. lbs.
before each lift.
• Lift only with equipment of ade-
quate lifting capacity.
FALLING • Never lift welder with gas
EQUIPMENT can cylinder attached.
cause injury. •
Never lift welder above personnel.
• Lift only with equipment of adequate lifting
capacity.
• Be sure machine is stable when lifting.
------------------------------------------------------------------------
WARNING