Lincoln Electric 225 Welder User Manual


 
A-10
INSTALLATION
WELDMARK 225
A-10
Connection of Weldmark 225 to premises wiring
must be done by a licensed electrician and must
comply with the National Electrical Code and all
other applicable electrical codes.
230 Volt
60 Hz.
3-Wire
Service
POWER
COMPANY
METER
230 VOLT
115 VOLT
115 VOLT
LOAD
N
NEUTRAL
BUS
GROUND
PREMISES
DISCONNECT AND
SERVICE
OVERCURRENT
PROTECTION
GND
N
NOTE: No. 8 COPPER CONDUCTOR CABLE SEE
NATIONAL ELECTRICAL CODE FOR ALTERNATE WIRE
SIZE RECOMMENDATIONS.
230 VOLT
GROUNDED CONDUCTOR
35AMP
230 VOLT
DOUBLE
POLE
CIRCUIT
BREAKER
DOUBLE POLE DOUBLE THROW
SWITCH RATING TO BE THE SAME
AS OR GREATER THAN PREMISES
SERVICE OVERCURRENT
PROTECTION.
50 AMP, 115/230
VOLT PLUG
NEMA TYPE 14-50
50 AMP, 115/230 VOLT
RECEPTACLE
Figure 1
CONNECTION OF WELDMARK 225 TO PREMISES WIRING
WARNING