Lincoln Electric IM956-A Welder User Manual


 
A-11
INSTALLATION
POWER WAVE® C300
A-11
TIG WELDING
(Figure A.7)
Tig uses Electrode Negative Polarity so for this appli-
cation, connect the Tig torch to the negative (-) output
stud and connect the work clamp to the positive (+)
output stud. The TIG torch gas connection should be
connected to the POWER WAVE® C300’s internal
gas supply connection. If required a foot amptrol can
be connected to the remote control receptacle.
SMAW WELDING
Most SMAW welding procedures use Electrode
Positive welding. For these applications, connect the
stick electrode holder to the positive (+) output stud
and connect the work clamp to the negative (-) output
stud.
Some SMAW welding procedures use Electrode
Negative Polarity. For these applications, connect the
stick electrode holder to the negative (-) output stud
and connect the work clamp to the positive (+) output
stud.
REMOTE CONTROL
RECEPTACLE
TO REMOTE CONTROL
RECEPTACLE
GAS SUPPLY
CONNECTION
TO GAS SUPPLY
CONNECTION
GAS HOSE
TIG TORCH
WORK PIECE
POWER CABLE
WORK CLAMP
FOOT AMPTROL
(OPTIONAL)
POSITIVE
STUD (+)
TO POSITIVE
STUD (+)
NEGATIVE
STUD (-)
TO NEGATIVE
STUD (-)
S
POOL GUN /
PUSH PULL
RECEPTACLE
FIGURE A.7