OPERATION
B-32
POWER WAVE® C300
Parameter Definition
P.103 View Software Version Information
Used for viewing the firmware versions for each board in the system. Press the right MSP
Button to enter the option. Rotate Set knob to select the desired board to read. Press the right
button again to read the firmware version. Press the left button to back out to select another
board. Rotate the SET knob to select another board, or press the left button to exit this option.
P.104 View Hardware Version Information
Used for viewing the hardware version for each board in the system. Press the right MSP
Button to enter the option. Rotate Set knob to select the desired board to read. Press the right
button again to read the hardware version. Press the left button to back out to select another
board. Press the left button again to exit this option.
P.105 View Welding Software Information
Used for viewing the Weld Set in the Power Source. Press the right MSP Button to read the
Weld Set version. Press the left button to back out and exit this option.
P.106 View Ethernet IP Address
Used for viewing the Ethernet Network IP address if there is an Ethernet board present in the
system. Press the right MSP Button to read the IP Address. Press the left button to back out
and exit this option. The IP address cannot be changed using this option.
P.107 View Power Source Protocol
Used for viewing the type of power source the feeder is connected to. Press the right MSP
Button to identify the power source as either LincNet or ArcLink. Press the left button to back
out and exit this option.
P.500 View Lockout Parameters
Originally used to prevent inadvertent changes of secure setup parameters, P.500 was previ-
ously used as a gateway to these parameters. Presently, this option does not exist in any setup
menu.
P.501 Encoder Lockout
Locks one or both of the upper knobs (encoders), preventing the operator from changing wire
feed speed, amps, volts or trim. The function of each upper knob depends on the selected weld
mode. When a constant current weld mode is selected (e.g. Stick, TIG, Gouge), the upper right
knob will always function as an on/off switch. This parameter can only be accessed using Weld
Manager or Power Wave Manager software.
P.502 Memory Change Lockout
Determines if the memories can be overwritten with new contents.
• No = Memories can be saved and limits can be configured (default).
• Yes = Memories cannot be changed - saving is prohibited and limits cannot be re-configured.
This parameter can only be accessed using Power Wave Manager.