Lincoln Electric LN-7 GMA WIRE FEEDERS Welder User Manual


 
A-22
INSTALLATION
LN-7 & LN-7 GMA
A-22
SHIELDING GAS HOOKUP (LN-7 GMA
or LN-7 with Optional K494 Gas Solenoid
Installed)
Gas under pressure is explosive. Always keep gas
cylinders in an upright position and to the
undercarriage or a stationary support. See
American National Standard Z-49.1, Safety In
Welding And Cutting, published by the American
Welding Society.
------------------------------------------------------------------------
Customer must provide a cylinder of shielding gas, a
pressure regulator, a flow control valve, and a hose
from the flow valve to the gas inlet fitting of the LN-7
GMA or the K494 Gas Solenoid Valve Kit installed on
the LN-7. Install per Figure A.20 and the following:
1. Connect the supply hose from the gas cylinder
flow valve outlet to the 5/8-18 female inert gas
fitting on the back panel of the LN-7.
2. Install the barbed fitting and union nut to the
5/8-18 female inert gas fitting on the front of the
LN-7. Connect 3/16 in. (4.8 mm) I.D. gas hose
from the gun to the barbed fitting.
When the gun is to be removed, this fitting can be
easily detached by loosening the union nut.
FIGURE A.20 SHIELDING GAS HOOKUP.
INERT
GAS
FITTING
GAS
HOSE
GAS
SUPPLY
HOSE
WARNING