MartinLogan MAC 500/E Work Light User Manual


 
23
Maintenance and Basic Service
MAC 500 E with electronic ballast
Electronic ballast models that come factory set for 100 V or 120 V have a 10 A main fuse, which is located near the
power switch. Units set at 210 V and above have a 6.3 A main fuse. Use a 6.3 A fuse when the WUDQVIRUPHU is set at
200, 210, 220, 230, or 240 V. Use a 10 A time-delay fuse when it is set at 100, 110, or 120 V.
No rewiring of the electronic EDOODVW is necessary; it works at any voltage between 100 and 250 volts, and at any fre-
quency between 50 and 60 Hz. The WUDQVIRUPHU must be tapped for the local supply voltage as shown below.
Updating software
The latest software for the MAC 500/E is available from your Martin dealer and the Martin Professional web site.
Please read the update notes bundled with the software. Update software is uploaded to the MAC 500/E using a Martin
uploader such as the MBPP1, or MP-2.
Normal upload
Connect the uploader to the fixture just like a controller. Under normal conditions, software can be installed from a
remote location - there is no need to set the MAC 500/E to boot mode. Please refer to the uploader manual for further
instructions.
Boot mode upload
If the data is corrupted during transmission, a check-sum error (CSER) will occur and after 15 seconds the fixture will
automatically switch to boot mode (
UPLd) and be ready for a boot-mode upload as described below and in the
uploader manual.
If a software upload to the MAC 500/E is interrupted, the fixture must be powered off for at least 10 seconds before a
new upload can be attempted. When powered on, a check-sum error will occur and it will automatically go into boot
mode, ready for a second upload attempt. Select boot mode upload on the uploader.
1
3
4
5
6
7 8 9
brown
red
black
blue
blue
220 V
1
3
4
5
6
7 8 9
brown
red
black
blue
blue
230 V
1
3
4
5
6
7 8 9
brown
red
black
blue
blue
240 V
1
4
5
7 8 9
black
blue
blue
100 V
3
red
brown
6
blue
1
4
5
7 8 9
black
blue
blue
110 V
3
red
brown
6
blue
1
4
5
7 8 9
black
blue
blue
120 V
3
red
brown
6
blue
MAC 500 E
Transformer
Settings
1
3
4
5
6
7 8 9
brown
red
black
blue
blue
200 V
1
3
4
5
6
7 8 9
brown
red
black
blue
blue
210 V