4-12. Setting Internal DIP Switches
1 DIP Switch S1
2 DIP Switch S4 (Not For Customer Use)
DIP switch S1 allows the user to make a num-
ber of choices affecting unit operation.
w Defining Motor Speed (S1-7 & 8)
Switches 7 and 8 allow the user to define
whether the motor in use is standard speed
(50-780 inches per minute), or high speed
(92-1435 inches per minute).
. Setting DIP switches allows the feeder to
display the proper wire speed. Setting
the DIP switches will not change the
speed range of the motors.
78
78
Position Settings And Results For DIP Switch S1
7 Off, 8 Off = Standard
speed motor (50-780 inch-
es per minute, or 1.2-19.8
meters per minute)
7 Off, 8 On = High speed
motor (92-1435 inches per
minute, or 2.3-36.4 meters
per minute)
. When DIP switch positions are changed, the
unit must be turned Off and then On again in
order for the new settings to be active. DIP
switches are only read on power up.