OM-1500-14 Page 19
4-13. Power Source Selection Menu
. When the feeder is turned on,
the Power Source Selection
Menu allows the operator to se-
lect a default power source.
Selecting a default power
source, automatically sets the
correct Vmin and Vmax set-
tings for adjusting the output
voltage of the power source.
First Time Feeder Is Turned On
The feeder automatically goes into
the Power Source Selection Menu.
The feeder displays “dELT” on the
Upper Display and “452” on the
Lower Display, meaning that a Del-
taweld 452 is the default power
source, and has a voltage range of
10V as Vmin and 38V as Vmax.
At power up, the operator has three
seconds to select a default power
source from the list shown on the
display. Operator may scroll
through the list of power sources by
using the Adjust control. After se-
lecting a power source the operator
has three seconds to change to a
different power source or begin
welding. After making a power
source selection, the operator may
press the Program Button to avoid
having to wait the three seconds.
When turning off the feeder, the de-
fault power source will be retained.
If voltage settings have already
been set with the Vmin and Vmax in
the Auxiliary Menu, selecting a de-
fault power source with the Power
Source Selection Menu overrides
the Vmin and Vmax voltage set-
tings.
Next Time Feeder Is Turned On
The feeder will display the last se-
lected default power source. The
operator has three seconds to se-
lect another power source, or press
the Program Button to exit the Pow-
er Source Selection Menu.
Disabling The Power Source
Selection Menu
Once the default power source has
been selected the Power Source
Selection Menu may be disabled
using the Auxiliary Menus. See
Section 5-12.
1 Upper Display
2 Lower Display
Program
Start
Crater
Pre/Postflow
Trigger Hold
Adjust
Volts Time (sec)
Wire Speed Amps
Sequence Setup
Dual Schedule
2
1
Non-CE Model Shown
* * Power Source
Upper Display
Lower Display
Deltaweld 452 dELT 452 Vmin =10 Vmax =38
Deltaweld 302 dELT 302 Vmin =10 Vmax =32
Deltaweld 652 dELT 652 Vmin =10 Vmax =44
Dimension 302 dIM 302 Vmin =10 Vmax =32
Dimension 452 dIM 452 Vmin =10 Vmax =38
Dimension 652 dIM 652 Vmin =10 Vmax =65
Dimension 1000 dIM 1000 Vmin =10 Vmax =60
XMT 304 XMT 304 Vmin =10 Vmax =35
XMT 456 XMT 456 Vmin =10 Vmax =38
Invision 354MP I354 MP Vmin =10 Vmax =35
Invision 456MP I456 MP Vmin =10 Vmax =38
Invision 456P I456 P Vmin =10 Vmax =38
PHOENIX 456
PHX 456 Vmin =10 Vmax =38
SUMMIT ARC 1000 SUM 1000 Vmin =25 Vmax =44
Voltage Range
** For any power sources not listed, pick a matching voltage range, or see Sec 4-12 to
set Vmin and Vmax.