Miller Electric Auto-Axcess 450 Welder User Manual


 
OM-210 540 Page 36
7-2. Diagnostics (Continued)
WELD WAIT
The weld wait error indicates unit was not
ready for a weld sequence. Press Jog/
Purge button to clear error.
MOTR COM
The motor communication error indi-
cates motor board lost data communica-
tions. Press Jog/Purge button to clear error.
If condition persists, contact nearest factory
authorized service agent.
PLS WAIT
The uim communication error indicates
user interface board lost data
communications. Press Jog/Purge button
to clear error. If condition persists, contact
nearest factory authorized service agent.
LOW WFS
The low wire feed speed error indicates
actual wire feed speed is lower than wire
feed speed command. Check for
obstructions in the wire feed system or a
faulty wire drive system. Press Jog/Purge
button to clear error.
ROBT MEM
The robot memory error indicates robot
lost memory data. Press Jog/Purge button
to clear error.
E STOP
The emergency stop error occurs if the
user presses an emergency stop button.
Reset the emergency stop button and press
Jog/Purge button to clear error. Only applies
to units equipped with E stop option.
RMD DONE
The RMD done message indicates the
RMD demo is completed. Pressing
Jog/Purge button will change the screen to
CYCL PWR on the display. Turn unit power
off and back on again.
OVER AVG
The over average error indicates that
current is outside the average range for the
set program parameters. Check and correct
program parameters. Press Jog/Purge
button to clear error.
UNIT COMM
The unit communication error indicates
the data bus on the PCM board is not
functioning properly. Press Jog/Purge
button to clear error.
OVER CRNT
The over current error indicates welding
power source primary current of the inverter
is too high. Turn welding power source off
and disconnect unit for servicing.
Attempting to reset the display to
continue welding may further damage
internal components. A complete
prepower check of the unit is needed
including resistance measurements of R1
and R8 resistors on welding power source
Interconnect board. Resistors should
measure 30K ohms. Visually inspect
electrolytic capacitors C1 and C2 for any
possible damage. In the event of an over
voltage condition, R1 and R8 could open
potentially causing an imbalance in the
power circuit. This condition would create
excessive current in the inverter primary
transformer and result in the OVER CRNT
error.
WELD
WAIT
MOTR
COM
PLS
WAIT
Indicates a weld
cycle wait error.
Indicates a motor
communication error.
Indicates a UIM
communication error.
LOW
Indicates a low WFS
command error.
WFS
ROBT
MEM
E
STOP
RMD
DONE
OVER
AVG
Indicates a CRC
robot memory error.
Indicates an
emergency stop error.
Indicates RMD
demo is done.
Indicates an over
average current error.
UNIT
COMM
Indicates a CRC
PCM bus error.
OVER
CRNT
Indicates an
overcurrent error.