Miller Electric Auto-Axcess 450 Welder User Manual


 
OM-210 540 Page 43
7-11. Diagnostic LED’s On Automation Interface Module PC9
LED Status Diagnosis
1 On Input signal On from robot for jog advance
Off Input signal Off from robot for no jog advance
2 On Input signal On from robot to energize contactor
Off Input signal Off from robot to not energize contactor
3 On Input signal On remote program A selected
Off Input signal Off remote program A not selected
4 On Input signal On remote program C selected
Off Input signal Off remote program C not selected
5 On Input signal On from E-stop board PC12 for no emergency stop
Off Input signal Off from E-stop board PC12 acknowledges E-stop is On from robot
6 On Spare 1 not assigned
Off Spare 1 not assigned
7 On Input signal On Autoset-C selected
Off Input signal Off Autoset-C not selected
8 On Input signal On Autoset-B selected
Off Input signal Off Autoset-B not selected
9 On Input signal On Remote Jog on from peripheral plug
Off Input signal Off Remote Jog off from peripheral plug
10 On Input signal On Remote Purge on from peripheral plug
Off Input signal Off Remote Purge off from peripheral plug
11 On Input signal On from robot for jog retract
Off Input signal Off from robot for no jog retract
12 On Input signal On from robot for purge
Off Input signal Off from robot for no purge
13 On Input signal On remote program B selected
Off Input signal Off remote program B not selected
14 On Input signal On Touch Sensor on from robot or peripheral plug
Off Input signal Off Touch Sensor off from robot or peripheral plug
15 On Spare 0 not assigned
Off Spare 0 not assigned
16 On Spare 2 not assigned
Off Spare 2 not assigned
17 On Input signal On Autoset-A selected
Off Input signal Off Autoset-A not selected
18 On Input signal On Autoset-D selected
Off Input signal Off Autoset-D not selected
19 On Input signal On Remote Retract on from peripheral plug
Off Input signal Off Remote Retract off from peripheral plug
20 On Input signal On Remote Water Flow on from peripheral plug
Off Input signal Off Remote Water Flow off from peripheral plug
21 On Input signal On from robot for no emergency stop
Off Input signal Off from robot for emergency stop
23 On Input signal On from relay K3 for welding power source ready and no detected errors present
Off Input signal Off from relay K3 for welding power source not ready, detected errors are present, or unit is
in operating mode preventing the weld ready signal from being enabled