7-3. Servicing Air Cleaner
aircleaner4 9/99 802 495 / Ref. S-0698-B
Y Stop engine.
1 Air Cleaner
2 Service Indicator (Optional)
3 Window
4 Reset Button
Service air cleaner element if red
band appears in window. A green
band means air cleaner is okay.
Press button to reset indicator.
Y Do not run engine without air
cleaner or with dirty element.
Clean or replace element if dirty or
damaged. Replace element yearly
or after six cleanings.
5 Dust Ejector
6 Dust Cover
7 Element
8 Safety Element (Optional)
9 Body
To Clean air filter:
Wipe off cover and body. Remove
cover and dump out dust. Wipe dust
from inside cover and body with
damp cloth. Remove element(s)
and reinstall cover.
Y Do not clean air cleaner body
with air hose.
Clean element(s) with compressed
air only. Keep nozzle at least 1 in
(25 mm) from inside of element.
Max. air pressure: 100 psi (690
kPa). Replace element(s) if it has
holes or damaged gaskets.
Reinstall element(s) and cover
(dust ejector down)