Miller Electric Big Blue 600D Welding System User Manual


 
OM-481 Page 13
SECTION 4 INSTALLATION
4-1. Installing Welding Generator
install1 7/02 Ref. ST-800 652 / Ref. ST-800 477-A / ST-158 936-A / S-0854
Electrically bond generator frame to
vehicle frame by metal-to-metal
contact.
GND/PE
1
2
Y Always securely fasten
welding generator onto
transport vehicle or trailer
and comply with all DOT and
other applicable codes.
Y Always ground generator
frame to vehicle frame to pre-
vent electric shock and static
electricity hazards.
Y If unit does not have GFCI re-
ceptacles, use GFCI-
protected extension cord.
1 Equipment Grounding
Terminal (On Front Panel)
2 Grounding Cable (Not
Supplied)
3 Metal Vehicle Frame
Connect cable from equipment
ground terminal to metal vehicle
frame. Use #10 AWG or larger
insulated copper wire.
3
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
OR
Movement Airflow Clearance Location
Grounding
OR
Y Do Not Lift Unit From End
4-2. Connecting The Battery
1/2 in
+
Y Connect Negative ()
Cable Last.
Tools Needed:
ST-153 654-B / Ref. SD-131 784-A / Ref. S-0756-B
OFF
START
RUN