Miller Electric Big Blue 600D Welding System User Manual


 
OM-481 Page 20
6-2. 240 Volt Duplex Receptacle (Optional)
Ref. ST-174 733 / ST-174 757
Y If unit does not have GFCI recep-
tacles, use GFCI-protected exten-
sion cord.
1 240 V 15 A AC Duplex
Receptacle RC1
Receptacle supplies 60 Hz single-phase
power at weld/power speed. Maximum out-
put from this receptacle is 3 kVA/kW.
2 120 V 20 A AC Duplex Receptacle
GFCI2 (Section 6-1)
3 Circuit Breakers CB1 And CB2
CB1 and CB2 protect the 120 V and 240 V
receptacles from overload. If CB1 or CB2
opens, the 240 V receptacle and one half of
the 120 V receptacle does not work. 120
volts may still be present at the 240 volt re-
ceptacle. Press button to reset breaker.
. If a circuit breaker continues to open,
contact a Factory Authorized Service
Agent.
4 Total Generator Power Output
Combined output of all receptacles limited
to 3 kVA/kW output of the generator.
EXAMPLE: If 10 A is drawn from the 240 V
receptacle, only 5 A is available at the 120
V receptacle:
(240 V x 10 A) + (120 V x 5 A) = 3.0 kVA/kW
13
4
2
SECTION 7 MAINTENANCE & TROUBLESHOOTING
7-1. Routine Maintenance
Follow the storage procedure in the engine owners manual if the unit will not be used for an
extended period.
Note
Recycle engine
fluids.
Y Stop engine before maintaining.
. See also Engine Manual and Mainte-
nance Label. Service engine more often
if used in severe conditions.
* To be done by Factory Authorized
Service Agent.
8 h
Check Fluid
Levels. See
Section 4-4.
Wipe
Up
Spills.
OIL
Full
Drain Water
From Fuel
System.
FUEL
WATER
50 h
Clean Air Filter.
See Section 7-3.
Clean And
Tighten
Weld
Terminals.