OM-491 Page 22
5-3. Remote Control (Optional)
1 Remote Amperage Adjust
Receptacle RC13
Connect optional remote control to
RC13 (see Section 4-10).
0774 / Ref. 154 862-A / Ref. 181 711-A / 802 160-A
Example: Combination Remote Amperage Control (Stick)
In Example:
Range = 125 to 320 A DC
Percentage Of Range = 50%
Max = About 223 A DC (50% of 125 to 320)
Adjust Optional Remote ControlSet Switches Set Range Set Percentage
Max (223 A DC)
Min (100 A DC)
1