5-2. Optional Auxiliary Power Receptacles
Y If unit does not have GFCI
receptacles, use GFCI-pro-
tected
extension cord.
.
Auxiliary power decreases as
weld current increases.
Set Fine Adjust control R1 at
10
for full auxiliary power
.
Combined
output of all
receptacles
limited to 8 kVA/kW rating of the
generator.
120
V
olt Receptacle Option
1
120 V 15 A AC Receptacles
RC2 And RC3
RC2
and RC3 supply
60 Hz single-
phase
power
at weld/power speed.
Maximum
output from RC2 or RC3
is
2.4 kV
A/kW (CSA: 1.8 kV
A/kW).
Circuit breaker protection is the
same
as standard receptacles.
South African And Australian
Receptacle Options
2
240 V 16 A AC South African
Receptacles RC1, RC2, And
RC3
3
240 V 15 A AC Australian
Receptacles RC1, RC2, And
RC3
Receptacles supply 60 Hz single-
phase
power
at weld/power speed.
Maximum
output
from each recep
-
tacle is 3.6 kVA/kW.
4 Circuit Breakers CB1, CB2,
CB3
CB1, CB2, and CB3 protect RC1,
RC2, and RC3 from overload. If a
circuit breaker opens, the recep-
tacle does not work. Press button
to
reset breaker
.
5 Circuit Breaker CB4
CB4 protects all the receptacles
from
overload. If CB4 opens,
none
of
the receptacles work.
.
If
a circuit breaker continues to
open, contact a Factory Au-
thorized
Service Agent.
1
2
4
5
3
4
5