Miller Electric CST 250 VRD Welding System User Manual


 
OM-220 812 Page 11
3-4. TIG (GTAW) Volt-Ampere Curve
Volt-ampere curves show minimum
and maximum voltage and
amperage output capabilities of
welding power source. Curves of
other settings fall between curves
shown.
LIFT ARC TIG (GTAW)
DC AMPS
DC VOLTS
0 50 100 150 200 250 300
0
5
10
15
20
25
30
35