Miller Electric DWF3 Welder User Manual


 
SECTION 4 MAINTENANCE AND REPAIR
OM-179 078 4-6
The standard setting for the DWF3 is 0.512 in. However, the following lengths may be obtained by inserting
jumpers from P1, P2, P3, and P4 on the U12 IC Circuit to +12V and ground as shown:
TABLE 4.3 AVAILABLE RETRACT LENGTHS
LENGTH DESIRED JUMPER CONNECTION TO +12 V AND GROUND FROM:
INCHES MM P1 P2 P3 P4
0.085 2.15 +12 GND GND GND
0.170 4.32 GND +12 GND GND
0.256 6.50 +12 +12 GND GND
0.341 8.67 GND GND +12 GND
0.427 10.86 +12 GND +12 GND
0.512* 13.00 GND +12 +12 GND
0.597 15.16 +12 +12 +12 GND
0.683 17.35 GND GND GND +12
0.768 19.51 +12 GND GND +12
0.853 21.67 GND +12 GND +12
0.939 23.85 +12 +12 GND +12
1.024 26.00 GND GND +12 +12
1.109 28.17 +12 GND +12 +12
1.195 30.35 GND +12 +12 +12
1.280 32.51 +12 +12 +12 +12
*Standard