OM-1314 Page 9
SECTION 2 – INSTALLATION
2-1. Specifications
Rated Welding
Output
Amperage
Range
Maximum
Open-Circuit
Voltage DC
Amperes Input at
Rated Load Out-
put 230 V, 60 Hz,
Single-Phase
KVA KW Weight
Overall
Dimensions
130 A @ 20.5 Volts
DC, 30% Duty Cycle
40 – 170
33
20.5
(0.27)*
4.7
(.05)*
4
(.04)*
95 lb
(43.1 kg)
Length: 17 in
(432 mm)
Width: 10 in
(254 mm)
Height: 15-1/2 in
(394 mm)
Wire Type
Solid/
Stainless
Flux Cored/
Aluminum
Calculated Wire
Speed Range At
No Load
Max Wire Feed Speed While Welding
And Dia
.023 – .035 in
(0.6 – 0.9 mm)
.030 – .045 in
(0.8 – 1.1 mm)
126 – 722 IPM
(3.2 – 18.3 m/min)
500 IPM
(12.7 m/min)
* While idling