Miller Electric 185 Welding System User Manual


 
. Complete Parts List available at www.MillerWelds.com
OM-4415 Page 27
SECTION 8 MAINTENANCE
. Follow the storage procedure in the engine owner’s manual if the unit will not be used for an extended period.
8-1. Routine Maintenance
. See Engine Manual and Maintenance Label
for important start-up, service, and storage
information. Service engine more often if
used in severe conditions.
Recycle engine
fluids.
Stop engine before maintaining.
n = Check Z = Change ~ = Clean l = Replace
* To be done by Factory Authorized Service Agent
Reference
Every
8
Hours
Section 5-3,
5-4
n Fuel Level n Oil Level ~ Oil, Fuel Spills
Every
25
Hours
Section 8-2
~ Air Cleaner Precleaner
Every
50
Hours
~ Weld Terminals
Every
100
Hours
Engine
Manual,
Section 8-2
Z Oil nl Air Cleaner Element ~ Cooling System n Spark Plug Gap
~ Battery Terminals (DX
Models)
n~ Spark Arrestor Screen
(Optional on DX Models)
Every
200
Hours
l Unreadable Labels
Every
300
Hours
Engine
Manual
nValve Clearance*
Every
500
Hours
Engine
Manual
nl Weld Cables n~ Slip Rings*
nl Brushes*