SECTION 4 INTRODUCTION
4-1. Specifications
Input
Power
Rated
Output
Voltage
Range in
CV Mode
Amperage
Range in
CC Mode
Max.
Open-
Circuit
Vlt
IP
Rating
RMS Amps Input at Rated Load
Output, 60 Hz 3-Phase at NEMA
Load Voltages and Class I Rating
KVA KW
Voltage
230 V 400 V 460 V
3-Phase 350 A at 34
VDC, 60%
Duty Cycle
1038 V 5425 A 75 VDC 23 36.1 20.6 17.8 14.2 13.6
*See Section 4-3 for Duty Cycle Rating.
4-2. Volt-Ampere Curves
217 836-A / 217 837-B
Volt-ampere curves show minimum
and maximum voltage and amper-
age output capabilities of welding
power source. Curves of other set-
tings fall between curves shown.
0
10
20
30
40
50
60
70
80
90
100
0 100 200 300 400 500
50%
75%
100%
25%
0%
AMPERAGE
VOLTS
A. CC Mode
GTAW
MAX
SMAW
MAX
SMAW
80A
ARC
CONTROL
GTAW
MN
0
10
20
30
40
50
60
70
80
90
100
0 100 200 300 400 500
VOLTS
B. CV Mode
AMPERAGE
MAX
MIN