OM-2254 Page 21
5-5. Remote 14 Receptacle Information
Socket* Socket Information
24 VOLTS AC
A 24 volts ac. Protected by circuit breaker CB2.
AJ
B
K
I
24 VOLTS AC
B Contact closure to A completes 24 volts ac
contactor control circuit.
B
K
I
C
L
NH
115 VOLTS AC
I 115 volts ac. Protected by circuit breaker CB1.
C
NH
D
M
G
E
F
115 VOLTS AC
J Contact closure to I completes 115 volts ac
contactor control circuit.
C Output to remote control; 0 to +10 volts dc, +10
volts dc in MIG mode.
REMOTE
OUTPUT
D Remote control circuit common.
OUTPUT
CONTROL
E 0 to +10 volts dc input command signal from
remote control.
M CC/CV select
A/V
AMPERAGE
F Current feedback; +1 volt dc per 100 weld am-
peres.
AMPERAGE
VOLTAGE
H Voltage feedback; +1 volt dc per 10 weld volts.
GND
G Circuit common for 24 and 115 volts ac circuits.
GND
K Chassis common.
*The remaining sockets are not used.
Ref. 803 879-B
1 115 V 10 Amp. AC
Receptacle
Power is shared between duplex
receptacle and Remote 14 recep-
tacle (see Section 5-5).
2 Circuit Breaker CB1
3 Circuit Breaker CB2
CB1 protects duplex receptacle
and 115 volts ac portion of Remote
14 receptacle from overload.
CB2 protects 24 volts ac portion of
Remote 14 receptacle from
overload.
Press button to reset breaker.
2 3
1
5-6. 115 Volts AC Duplex Receptacle And Circuit Breakers