PARAMETERS
21
Func-
tion
Parameter
Number
Name Setting Range
Minimum
Setting
Increments
Factory Setting
Refer To
Page:
<Note9>
150
Output current detection level
0 to 200%
0.1%
150%
120
151
Output current detection period
0 to 10 sec
0.1 sec
0
120
152
Zero current detection level
0 to 200%
0.1%
5.0%
121
Current
detection
153
Zero current detection period
0 to 1 sec
0.01 sec
0.5 sec
121
154
Voltage reduction selection during stall
prevention operation
0, 1
1
1
121
155
RT activated condition
0, 10
1
0
122
*156
Stall prevention operation selection
0 to 31 (Odd), 100
1
0
122
157
OL signal waiting time
0 to 25 sec, 9999
0.1 sec
0
124
Sub functions
158
AM terminal function selection
1 to 3, 5 to 14,
17, 18, 21
1
1
124
Additional
function
160
User group read selection
0, 1, 10, 11
1
0
125
162
Automatic restart after instantaneous
power failure selection
0, 1, 2
1
0
125
163
First cushion time for restart
0 to 20 sec
0.1 sec
0 sec
125
164
First cushion voltage for restart
0 to 100%
0.1%
0%
125
Automatic restart after
instantaneous power
failure
*165
Restart stall prevention operation level
0 to 150%
0.1%
150%
125
170
Watt-hour meter clear
0
0
126
Initial
monitor
171
Actual operation hour meter clear
0
0
126
173
User group 1 registration
0 to 999
1
0
125
174
User group 1 deletion
0 to 999, 9999
1
0
125
175
User group 2 registration
0 to 999
1
0
125
User functions
176
User group 2 deletion
0 to 999, 9999
1
0
125
180
RL terminal function selection
0 to 99, 9999
1
0
126
181
RM terminal function selection
0 to 99, 9999
1
1
126
182
RH terminal function selection
0 to 99, 9999
1
2
126
183
RT terminal function selection
0 to 99, 9999
1
3
126
184
AU terminal function selection
0 to 99, 9999
1
4
126
*185
JOG terminal function selection
Already Assigned
126
186
CS terminal function selection
0 to 99, 9999
1
6
126
190
RUN terminal function selection
0 to 199, 9999
1
0
128
191
SU terminal function selection
0 to 199, 9999
1
1
128
192
IPF terminal function selection
0 to 199, 9999
1
2
128
193
OL terminal function selection
0 to 199, 9999
1
3
128
194
FU terminal function selection
0 to 199, 9999
1
4
128
Terminal assignment functions
195
A, B, C terminal function selection
0 to 199, 9999
1
99
128
Additional
function
199
User's initial value setting
0 to 999, 9999
1
0
130
Pr.185 : This terminal is already assigned in Factory. User can not use.