Multiquip EHTX44Y5 Cordless Sander User Manual


 
PAGE 20 — EHTX44Y RIDE-ON TROWEL • OPERATION MANUAL — REV. #0 (01/16/13)
SETUP
TROWEL SETUP INSTRUCTIONS
The purpose of this section is to assist the user in the setting
up of a NEW trowel. If your trowel is already assembled
(seats, handles, knobs and battery), then this section can
be skipped.
Before packaging and shipping this Whiteman Ride-On
Power Trowel was run and tested at the factory. If there are
problems with the trowel, please let us know.
SEAT ASSEMBLY
The seat is not installed on the trowel for shipping purposes.
To attach the seat perform the following:
1. Remove the seat from the protective wrapping.
2. Remove the bolts on the bottom of the seat, and place
seat on the seat mounting plate, then insert the bolts
through the holes or slots on the seat mounting plate
and tighten.
BATTERY SETUP
This trowel was shipped with a wet charged battery. This
battery may need to be charged for a brief period of time
as per the manufacturer instructions.
To install the battery on the trowel, make sure that the
battery is well seated in the battery box and the terminals
are properly connected. The positive cable, normally
RED, is associated with the "+" symbol on the battery. The
negative cable, normally BLACK, is associated with the "-"
symbol on the battery, (Figure 5). Connect the positive cable
to the positive terminal on the battery first, then connect the
negative cable to the negative terminal. Close the plastic
battery box cover and secure the battery box.
NOTICE
The new ride-on trowel cannot be put into service until
the setup installation instructions are completed. These
setup instructions only need to be performed at the time
of unpacking a NEW trowel.
NOTICE
EHTX trowels have a seat that is mounted on tracks,
similar to an automobile seat. This seat can be adjusted
fore and aft via the control lever under the front of the
seat.
Figure 5. Battery Cable Orientation
DANGER
Use all safety precautions specified by the battery
manufacturer when working with the battery.
Flammable, explosive gas. (produces
hydrogen gas while charging or during
operation). Keep area around battery well
ventilated and keep from any fire source.
Battery electrolyte contains corrosive, toxic
chemical. (dilute sulfuric acid). Avoid
contact with eyes and skin.
Shock or Fire due to electric short-
circuit. Disconnect battery cables before
inspecting electrical system and never
"spark" battery terminals to test for charge.
NOTICE
ALWAYS be sure the battery cables are properly
connected to the battery terminal. The RED cable is
connected to the positive terminal of the battery, and
the BLACK cable is connected to the negative terminal
of the battery.
CAUTION
Use all safety precautions specified by the battery
manufacturer when working with the battery. Reference
the safety section in this manual for additional battery
safety information.
NEGATIVE
CABLE (BLACK)
BATTERY
POSITIVE
CABLE (RED)