Multiquip SP303516 Saw User Manual


 
MQ SP-3035 CONCRETE SAW — OPERATION AND PARTS MANUAL — REV. #3 (09/29/06) — PAGE 28
MQ SP-3035 CONCRETE SAW
Fueling the Saw
The 3000 Series saws feature a five-gallon clear molded plastic fuel tank with a sight gauge,
central drain, and shutoff valve. The gas tank cap is located at the front of the saw.
WARNING
To prevent damage to the impeller of a belt driven water pump, do not
run the engine with the water pump switch on, unless the water
supply is connected and water is flowing.
When storing the saw during freezing weather, blow out the water
lines to prevent damage to the water delivery system.
CAUTION
Use 90+ Octane Unleaded Gasoline Only
Fig. 14 — Fueling the Saw
Gas Tank Cap
Fuel Tank
Fuel Shut-off
Valve
Fuel Sight
Gauge slots
Inline Fuel
Filter