www.norcold.com/cda 9N6XX/N8XX ModelsRefrigerator Service Manual
N62X/N82X DISPLAYED FAULT CODES
Probable Cause
ReferenceCode
See page 16.
See page 19.
See page 20.
Flashing
Temp
Setting
See page 13.
See page 18.
See page 16.
See page 12.
See page 14.
See page 13.
See page 11.
Blank
Display
Screen
See pages
21 & 37.
Refrigerator turned off.
No 12 Vdc to refrigerator.
F1 fuse open.
DC voltage low.
Flame sense circuit failure.
Burner failed to ignite or reignite.
DC voltage high.
AC relay stuck closed.
No AC power available to refrigerator.
AC cord not plugged into power board.
F3 fuse open.
AC heater failed open.
Fresh food compartment door open more then 2 minutes.
Lamp reed relay switch faulty.
Back-up operating system.
No cooling detected by the controls.