Norcold N62X Work Light User Manual


 
www.norcold.com/cda 39N6XX/N8XX ModelsRefrigerator Service Manual
Cooling System Diagnostic Flowchart
!
WARNING:
Do not operate the refrigerator if the
cooling unit is leaking or a leak is
suspected.
!
WARNING:
Do not bypass or modify the refrigerator’s controls
or components to diagnose the cooling system. Do
not wire the heater(s) direct. The heater is supplied
power through a fused circuit.
Check cooling unit.
Correct ventilation to meet
installation requirements
.
YES
NO
Check heat input.
NO
NO
Correct heat input device to
meet specifications
.
YES
Signs of leak(s):
Yellow residue inside or at the rear of the
refrigerator.
Ammonia smell.
NO
Level refrigerator as outlined
in Owner's Manual and
specifications.
YES
Continued on page 40.
YES
Replace cooling unit.
Refrigerator
operating leveled?
Maximum off-level limits:
3 degrees side to side.
6 degrees front to back.
Check (as required):
AC heater voltage and amp draw.
DC heater voltage and amp draw.
(3-way units only).
Burner, orifice, flue, deflector cap, flue baffle.
LP gas pressure.
Ventilation as
per installation
instructions?
Any signs of leak?
Heat input device
operating within
specification?