Troubleshooting
Trouble Probable Cause Remedy
Not connected to power source. Check plug connection.
Fuse blown, or circuit breaker tripped. Replace fuse, or reset circuit breaker.
Cord damaged. Replace cord.
Feeder will not start.
Starting capacitor bad. Replace starting capacitor.
Wrong gears installed for the desired
feed rate.
Install correct gears in proper
positions. [page 13]
Extension cord too light or too long.
Replace with adequate size and
length cord. [page 12]
Feed speed is not
sufficient; machine
has low power.
Low current from electrical supply. Contact a qualified electrician.
Workpiece jams while
feeding it beneath
rollers.
Rollers too low. Raise feeder.
Workpiece slips while
passing under rollers.
Rollers too high, no traction. Lower feeder.
Rollers slip on
workpiece.
Grease or debris on rollers. Clean rollers.
Replacement Parts
Replacement parts are listed on the following pages. To order parts or reach our service department, call
1-800-274-6848, Monday through Friday (see our website for business hours, www.powermatic.com).
Having the Model Number and Serial Number of your machine available when you call will allow us to
serve you quickly and accurately.