Motor Specifications and Electrical Requirements
Power Supply and Motor
Specifications
WARNING: To reduce the risk of
electrical hazards, fire hazards or
damage to the tool, use proper
circuit protection. Your tool is
wired at the factory for operation
using the voltage shown. Con-
nect tool to a power line with the
appropriate voltage and a 15-
amp branch circuit. Use a 15-
amp time delay type fuse or cir-
cuit breaker. To reduce the risk of
shock or fire, if power cord is
worn or cut, or damaged in any
way, have it replaced immedi-
ately.
The A-C motor used on this tool is a uni-
versal non-reversible type, having the fol-
lowing specifications.
General Electrical Connections
DANGER: To reduce the risk of
electrocution:
1. Use only identical replace-
ment parts when servicing.
Servicing should be per-
formed by a qualified service
technician.
2. Do not use in rain or where
floor is wet.
This tool is intended for
indoor residential use only.
WARNING: Do not permit fingers
to touch the terminals of plug
when installing or removing the
plug to or from the outlet.
110-120 Volt, 60 Hz. Tool Information
The plug supplied on your tool may not fit
into the outlet you are planning to use.
Your local electrical code may require
slightly different power cord plug connec-
tions. If these differences exist refer to
and make the proper adjustments per
your local code before your tool is
plugged in and turned on.
In the event of a malfunction or break-
down, grounding provides a path of least
resistance for electric current to reduce
the risk of electric shock. This tool is
equipped with an electric cord having an
equipment-grounding conductor and a
grounding plug, as shown. The plug must
be plugged into a matching outlet that is
properly installed and grounded in accor-
dance with all local codes and ordi-
nances.
Do not modify the plug provided. If it will
not fit the outlet, have the proper outlet
installed by a qualified electrician.
Voltage 120
Amperes 15
Hertz (Cycles) 60
Phase Single
RPM 4000
Rotation of Shaft Counterclockwise
(Blade End)