Bostitch BTFP02028 Air Compressor User Manual


 
8 9
5c
Axle Bolt
AxleNut
Wheel
Wheel
Bumper
Bolt
Nut
5b5a
INSTALLING HOSES
Risk of unsafe operation. Firmly grasp hose in hand when installing or discon-
necting to prevent hose whip.
1. EnsureRegulatedPressureGauge(C)reads0psi.
 2. GraspthehoseattheQuickConnect(E)plugandpushtheplugintotheQuickConnect(E)
body. Coupler will snap into place.
3. Grasp the hose and pull to ensure coupler is seated.
DISCONNECTING HOSES
Risk of unsafe operation. Firmly grasp hose in hand when installing or discon-
necting to prevent hose whip.
1. EnsureRegulatedPressureGauge(C)reads0psi.
2. PullcoupleronQuickConnect(E)bodybacktoreleaseQuickConnect(E)plugonhose.
GROUNDING INSTRUCTIONS (FIG. 2)
L
M
K
FIG. 2
RiskofElectricalShock.Intheevent
of a short circuit, grounding reduces the risk of
shock by providing an escape wire for the electric
current. This air compressor must be properly
grounded.
The portable air compressor is equipped with a
cord having a grounding wire with an
appropriate grounding plug.
1. Thecordsetandplug(M)withthis unitcon-
tains a grounding pin (L).
This plug MUST beusedwithagroundedoutlet(K).
IMPORTANT: The outlet being used must be installed and grounded in accordance with all local
codes and ordinances.
2. Ensuretheoutletbeingusedhasthesameconfigurationasthegroundedplug.
DO NOT USE AN ADAPTER.
3. Inspect the plug and cord before each use. Do not use if there are signs of damage.
4. If these grounding instructions are not completely understood, or if in doubt as to whether
the compressor is properly grounded, have the installation checked by a qualified
electrician.
Risk of Electrical Shock. IMPROPER GROUNDING CAN RESULT IN ELECTRICAL
SHOCK.
• Donotmodifytheplugprovided.Ifitdoesnotfittheavailableoutlet,acorrectoutlet
should be installed by a qualified electrician.
• RepairstothecordsetorplugMUSTbemadebyaqualifiedelectrician.