14 CORRECTION OF MALFUNCTIONS
MALFUNCTION CAUSE REMEDY
The unit will not start
•
No mains voltage
•
Device overheated
•
Check
•
Unplug the power plug, let the device cool
down approx. 30 minutes, do not bend the
hose, check the air lter, do not cover the intake
slots
No coating material emerges
from the nozzle
•
Nozzle clogged
•
Material volume setting too low
•
Paint container seal damaged
•
No pressure build-up in container
•
Container empty
•
Ventilation hose loose/damaged
•
Feed tube loose
•
Feed tube / feed tube lter clogged
•
Air vent on feed tube blocked
•
Diaphragm stuck
•
Clean
•
Increase volume
•
Replace
•
Tighten container
•
Rell
•
Insert or replace
•
Insert
•
Clean or use another lter
•
Clean
•
Remove and clean (see section 13.2)
Coating material drips from the
nozzle
•
Air cap, nozzle or needle soiled
•
Spray attachment incorrectly
assembled
•
Nozzle loose
•
Nozzle seal worn
•
Nozzle worn
•
Needle worn
•
Clean
•
Assemble correctly (see section 12.1)
•
Tighten Union nut
•
Change
•
Change
•
Use new spray attachment
Atomisation too coarse
•
Material volume too large
•
Nozzle contaminated
•
Viscosity of coating material too high
•
Too little pressure build-up in
container
•
Air lter heavily soiled
•
Amount of air too low
•
Air hose damaged
•
Reduce volume
•
Clean
•
Dilute further
•
Tighten container
•
Change (see section 13.1)
•
Increase volume
•
Check and replace if necessary
Spray jet pulsates
•
Coating material in container running
out
•
Nozzle seal worn
•
Air lter heavily soiled
•
Feed tube loose
•
Feed tube / feed tube lter clogged
•
Rell
•
Replace
•
Change (see section 13.1)
•
Insert
•
Clean or use another lter
Coating material causes “paint
tears
•
Too much coating material applied
•
Distance too small
•
Incorrect spray attachment
•
Reduce volume
•
Increase distance
•
Use another spray attachment
Excessive paint mist (overspray)
•
Distance to the object too large
•
Too much coating material applied
•
Amount of air too high
•
Coating substance over-diluted
•
Incorrect spray attachment
•
Reduce distance
•
Reduce volume
•
Reduce volume
•
Reduce degree of dilution
•
Use another spray attachment
Paint in the ventilating hose
•
Diaphragm soiled
•
Diaphragm defective
•
Clean the diaphragm (see section 13.2)
•
Replace the diaphragm (see section 13.2)