Wagner SprayTech 239012 Sander User Manual


 
8
FinishControl 5000
AUS
14 CORRECTION OF MALFUNCTIONS
MALFUNCTION CAUSE REMEDY
The unit will not start
No mains voltage
Device overheated
Check
Unplug the power plug, let the device cool
down approx. 30 minutes, do not bend the
hose, check the air lter, do not cover the intake
slots
No coating material emerges
from the nozzle
Nozzle clogged
Material volume setting too low
Paint container seal damaged
No pressure build-up in container
Container empty
Ventilation hose loose/damaged
Feed tube loose
Feed tube / feed tube lter clogged
Air vent on feed tube blocked
Diaphragm stuck
Clean
Increase volume
Replace
Tighten container
Rell
Insert or replace
Insert
Clean or use another lter
Clean
Remove and clean (see section 13.2)
Coating material drips from the
nozzle
Air cap, nozzle or needle soiled
Spray attachment incorrectly
assembled
Nozzle loose
Nozzle seal worn
Nozzle worn
Needle worn
Clean
Assemble correctly (see section 12.1)
Tighten Union nut
Change
Change
Use new spray attachment
Atomisation too coarse
Material volume too large
Nozzle contaminated
Viscosity of coating material too high
Too little pressure build-up in
container
Air lter heavily soiled
Amount of air too low
Air hose damaged
Reduce volume
Clean
Dilute further
Tighten container
Change (see section 13.1)
Increase volume
Check and replace if necessary
Spray jet pulsates
Coating material in container running
out
Nozzle seal worn
Air lter heavily soiled
Feed tube loose
Feed tube / feed tube lter clogged
Rell
Replace
Change (see section 13.1)
Insert
Clean or use another lter
Coating material causes “paint
tears
Too much coating material applied
Distance too small
Incorrect spray attachment
Reduce volume
Increase distance
Use another spray attachment
Excessive paint mist (overspray)
Distance to the object too large
Too much coating material applied
Amount of air too high
Coating substance over-diluted
Incorrect spray attachment
Reduce distance
Reduce volume
Reduce volume
Reduce degree of dilution
Use another spray attachment
Paint in the ventilating hose
Diaphragm soiled
Diaphragm defective
Clean the diaphragm (see section 13.2)
Replace the diaphragm (see section 13.2)
CORRECTION OF MALFUNCTIONS