33
C_00157
10
B_04124
2
10
3
B_04078
2
OPERATING MANUAL
VERSION 03/2013 ORDER NUMBER DOC 2310799
Before every start-up, the following points should be observed as laid down in the
operating manual:
- Check the permissible pressures.
- Check all connecting parts for leaks.
- Check hoses for damage.
It should be ensured that the device is in the following state before carrying out any work
on it:
- Interrupt the air supply (2).
- Depressurize the air motor (pull the ring on the safety valve (10)).
- Relieve the pressure from the uid section.
EMERGENCY STOP
In the case of unforeseen occurrences
the ball valve (2) should be closed
immediately.
Open the safety valve (10) and relieve the
material-conveying parts completely of
pressure via the return valve (3).
closed
open