Wagner SprayTech 40-15 Power Screwdriver User Manual


 
35
B_04079
5
1
6
4
2
7
3
8
9
OPERATING MANUAL
VERSION 03/2013 ORDER NUMBER DOC 2310799
6.5.3 BASIC FLUSHING
Before each basic  ushing, the nozzle must be removed from the pistol. The data in the
gun's operating manual are to be observed.
With AirCoat systems, carry out the basic  ushing of the system without atomizing air (8)
.
1 Place empty container (5) under return tube (4).
2 Place suction hose (7) in the container with  ushing agent (6).
3 Open return valve (3).
4 Slowly open the ball valve (2).
5 Adjust the air pressure on the pressure regulator (1) so that the pump runs smoothly.
6 Flush the system until clean  ushing agent  ows into the container (5).
7 Close ball valve (2).
8 Close return valve (3).
9 Point the gun (9), without nozzle, into container (5) and open it.
10 Slowly open the ball valve (2).
11 Rinse until clean  ushing agent  ows from the gun.
12 Close ball valve (2).
13 Relieve the system pressure, either by opening the return valve (3) or via the trigger
on the gun (9).
14 When there is no pressure remaining in the system, close the gun (9) or the return
valve (3).
15 Secure the gun.
16 Dispose of the contents of the container (5) according to the local regulations.
open
closed