Wagner SprayTech 508028 Paint Sprayer User Manual


 
6. Turn the pressure control knob counterclockwise to its
lowest setting.
7. Turn the PRIME/SPRAY knob to PRIME.
8. Trigger the gun to remove any pressure which may still be
in the hose.
9. Lock the gun by turning the gun trigger lock so that it is
parallel to the gun body.
10. Turn the motor switch to OFF.
Clearing the Gun
1. Remove the spray gun from the paint hose using two
adjustable wrenches.
2. Remove the filter housing from the gun. Place the gun
and the filter assembly into a container of water or solvent
to soak.
3. Cover the paint container and set it aside.
4. Clean the spray tip and gun filter with a soft brush.
Assemble the spray tip in the cleaning position with the
arrow pointing to the back of the gun.
5. Attach the paint hose to the gun and tighten using two
wrenches.
6. Turn the motor switch to ON.
7. Unlock gun trigger by turning the gun trigger lock so that it
is parallel to the gun handle.
8. Turn the PRIME/SPRAY knob to SPRAY and point the gun
to the side of the cleaning bucket.
9. Trigger the gun and gradually turn the pressure control
knob clockwise to 1/2 pressure. Continue to trigger the
gun for approximately 30 seconds.
10. Turn the pressure control knob counterclockwise to its
lowest setting.
11. Turn the PRIME/SPRAY knob to PRIME.
12. Trigger the gun to remove any pressure which may still be
in the hose.
13. Lock the gun by turning the gun trigger lock so that it is
parallel to the gun body.
14. Turn the motor switch to OFF.
10 © SprayTECH Corporation. All rights reserved.
Final Cleanup
1. Remove the tip assembly.
2. Turn the motor to ON.
3. Turn the PRIME/SPRAY knob to SPRAY.
4. Turn the pressure control knob clockwise to 1/2 power.
5. Trigger the gun into the cleaning bucket until the hopper is
empty.
6. Refill the hopper and continue flushing the system until
the solution coming out of the gun appears clean.
7. Lock the gun and turn the pressure control knob
counterclockwise to its lowest setting.
8. Turn the PRIME/SPRAY knob to PRIME.
9. Remove the hopper from the inlet valve.
10. Clean the threads of the inlet valve with a damp cloth.
11. Fill the inlet valve with a light household oil. Slowly
increase the pressure to distribute the oil through the pump.
12. Turn the PRIME/SPRAY knob to SPRAY to distribute the
oil.
13. Turn the pressure control knob counterclockwise to its
lowest setting.
14. Turn the PRIME/SPRAY knob to PRIME.
15. Trigger the gun to remove any pressure which may still be
in the hose.
16. Lock the gun by turning the gun trigger lock so that it is
parallel to the gun body.
17. Turn the motor switch to OFF.
18. Remove and clean the hopper filter in clean water or the
appropriate solvent. Use a soft brush.
19. Return the hopper filter to its postion in the hopper and
replace the hopper on the inlet valve.
20. Wipe the entire unit, hose and gun with a damp cloth to
remove accumulated paint.
NOTE: Proper cleaning and oiling of the pump after
use are the most important steps you can take
to insure proper operation after storage.
SPRAY
PRIME
English