Wagner SprayTech HC950 SSP Paint Sprayer User Manual


 
 
GB
Description of unit
HC 950
(0528501)
HC 950-SSP
(0528503)
HC 970
(0528509)
HC 970-SSP
(0528507)
Voltage
230 V~, 50 Hz: R R
400 V, 50 Hz, V3~: R R
Fuse protection
16 A: R R R R
Power cord
 – 6 m: R R
 – 6 m: R R
Capacity
3.6 kW: R R
5.5 kW: R R
Max operating pressure
25 MPa (250 bar): R R R R
Maximum volume ow
6.6 l/min: R R
10 l/min: R R
Volume ow at 12 MPa (120 bar)
5.2 l/min: R R
10 l/min: R R
Max. size of tip with a spray gun
0.052 inch – 1.30 mm: R R
0.056 inch – 1.42 mm: R R
Fluid outlet tting
3/8 inch – 9.5 mm: R
 R R R
Max. temperature of the coating material
 R R R R
Max. Viscosity
50.000 mPa·s: R R
65.000 mPa·s: R R
Filter insert (standard equipment)
0 Mesh: R R R R
Weight:
83 kg R
84.5 kg R
100 kg R
103 kg R
Hydraulic oil lling quantity
 R R R R
Max. tire pressure
0.2 MPa (2 bar): R R R R
Special high-pressure hose
 R
 R R R
Hose whip
 R R R
Dimensions L x W x H
 R R
 R R
Max. sound pressure level:
80 dB (A)* R R
88 dB (A)* R R
* Place of measurement: 1 m distance from unit and 1.60 m above reverberant oor, 12 MPa (120 bar) operating pressure.