Wagner SprayTech HC950 SSP Paint Sprayer User Manual


 
 
GB

11. Appendix
11.1 Selection of tip

In many cases the correct tip can only be determined by means of a spraying test.
Some rules for this:

If streaks appear in the spray jet the spraying pressure is either too low or the viscosity of the coating material to high.
Remedy
  
small tip = high pressure

11.2 Servicing and cleaning of Airless hard-metal tips
Standard tips



The following points must be observed to keep the tip clean and ready for use:
 k Circulation).
2. Switch o the gasoline engine.
3. Dismount the tip from the spray gun.
4. Place tip in an appropriate cleaning agent until all coating material residue is dissolved.
5. If there is pressure air, blow out tip.
6. Remove any residue by means of a sharp wooden rod (toothpick).
 
11.3 Spray gun accessories
Flat jet adjusting tip
up to 250 bar (25 MPa
Contact protection
for the at jet adjustment tip
0097 294
Tip extension
with slewable
knee joint
(without tip)
Tip extension
Length: 100 cm 0096 015
Length: 200 cm 0096 016
Length: 300 cm 0096 017
0556 051 0556 074
0556 052 0556 075
0556 053 0556 076
0556 054 0556 077
Tip
marking
Bore mm
Spray width at about 30 cm
removal of spray object
Pressure 100 bar (10 MPa)
Use
Flat jet
adjusting tip
Order No.
15 0.13 - 0.46 5 - 35 cm Paints 0999 057
20 0.18 - 0.48 5 - 50 cm Paints, llers 0999 053
28 0.28 - 0.66 8 - 55 cm Paints, dispersions 0999 054
41 0.43 - 0.88 10 - 60 cm Rust protection paints
- dispersions
0999 055
49  10 - 40 cm Large-area coats 0999 056