Xantrex Technology 1000 Battery Charger User Manual


 
1–30 975-0395-01-01
This guide for use by qualified installers only
Testing in Shore Power Mode
To test the Freedom HF in shore power mode:
With the appliance from the previous test still connected and
operating, connect the shore power source.
The Freedom HF transfers the appliances to shore power. The status
LED on the display panel will change from yellow to a ten-second
flashing yellow and then green.
If the appliance operates, your installation is successful.
Note: If the Inverter button on the Freedom HF is turned ON, the Freedom HF
will automatically supply the appliances with inverter power if the shore power
source fails or becomes disconnected.
If the Inverter button on the Freedom HF is turned ON and shore power voltage is
too low (less than 90 volts AC), the unit will transfer to inverter power to continue
running your appliances.
WARNING: Shock hazard
Whether or not the Inverter button is turned ON, shore power will pass through
the Freedom HF to the output when shore power is within normal operating
range.
FreedomHF_IC_01-Installation.fm Page 30 Monday, December 24, 2007 9:47 AM