Xantrex Technology 1000 Battery Charger User Manual


 
2–4 975-0395-01-01
This guide for use by qualified installers only
To adjust the alarm setting:
By default the alarm is set to ON.
Press and hold the Select button for two seconds.
The display shows “AL0” indicating that the alarm is OFF.
The display shows “AL1” indicating that the alarm is ON.
Whenever the alarm setting is changed, the display will temporarily show
either “AL0” or “AL1” and after a few seconds will return to displaying
what was on the screen prior to the adjustment.
To adjust the charging current:
By default the charging current is set to:
20A for the Freedom HF 1000
40A for the Freedom HF 1800
1. Press and hold the Inverter button for five seconds.
The unit will go into Charge Current Setting Mode.
2. Press the Select button to toggle between the different Amp ratings.
251020 for the Freedom HF 1000
2102040 for the Freedom HF 1800
3. Choose the desired charging current by stopping at the value shown
on the display. To maximize unit performance, see Table 2-1
“Charging Current Guidelines” below.
Wait for five seconds and the charging current is set.
Note: The alarm setting will reset to its default setting when the
Freedom HF’s Inverter button is turned OFF then turned ON
again.
FreedomHF_IC_02-Configuration.fm Page 4 Monday, December 24, 2007 9:48 AM