3–4 975-0390-01-01
To adjust the alarm setting:
By default the alarm is set to ON.
• Press and hold the Select button for two seconds.
The display shows “AL0” indicating that the alarm is OFF.
The display shows “AL1” indicating that the alarm is ON.
Whenever the alarm setting is changed, the display will temporarily show
either “AL0” or “AL1” and after a few seconds will return to displaying
what was on the screen prior to the adjustment.
To adjust the charging current:
By default the charging current is set to:
• 20A for the Freedom HF 1000
• 40A for the Freedom HF 1800
1. Press and hold the Inverter button for five seconds.
The unit will go into Charge Current Setting Mode.
2. Press the Select button to toggle between the different Amp ratings.
• 2 — 5 — 10 — 20 for the Freedom HF 1000
• 2 —10 — 20 — 40 for the Freedom HF 1800
3. Choose the desired charging current by stopping at the value shown
on the display. To maximize unit performance, see Table 3-1
“Charging Current Guidelines” below.
Wait for five seconds and the charging current is set.
After the charging current is set, the display will return to displaying what
was on the screen prior to the adjustment.
Note: The alarm setting will reset to its default setting when the
Freedom HF’s inverter button is turned OFF then turned ON again.