4–2 975-0390-01-01
Display Panel Operation
The Freedom HF features a display panel with three-digit LED display to
show inverter, AC source, and battery status information.
Feature Description
1 Inverter button
• Press and hold for one second to turn the Freedom HF’s Inverter function ON or OFF
(when AC Shore Power is NOT present.)
• Press and hold for five seconds to go into Charger Current Select Mode.
2 Three-digit LED display screen shows status information and fault codes.
3 Status LED Indicates the mode of operation with a three-color LED.
• Green pertains to Utility status.
• Solid indicates the Freedom HF is in shore power mode and battery is fully charged.
• Flashing indicates the Freedom HF is in shore power mode and the unit is currently
charging the battery.
• Yellow pertains to Battery status.
• Solid indicates the Freedom HF is in inverter mode and using the battery to provide
AC power.
• Flashing indicates the Freedom HF is in inverter mode but AC shore power is
detected thus transferring to shore power mode within 20 seconds.
• Red indicates a Fault condition and the Freedom HF has shut down. See
“Troubleshooting Reference” on page 5–8.
4 Select button
• In Inverter mode, press the button to choose what appears in the three-digit LED
display: Input Voltage, Input Current, or Output Power. See “To adjust what is
being displayed on the screen:” on page 3–3.
NOTE: A corresponding LED lights up for each of the three items.
• In an Alarm condition, press and hold for two seconds to disable (or enable) the audible
alarm. See “To adjust the alarm setting:” on page 3–4.
• In Charger Current Select Mode, press to select the charger current. See “To adjust the
charging current:” on page 3–4.
FREEDOM
HF 1000
Input Voltage (V)
Select
STATUS
Battery
Fault
Utility
Input Current (A)
Output Power (kW)
4
1
2
3
Freedom HF 1000 shown
See NOTE in Feature # 4 below.